Multi-brand automation spare parts and integration support.Email: contact@mail.warrior-tech.com
Company & Events

WarriorZ at CIPM Qingdao 2025: Booth N2-78 Record

A corrected Booth N2-78 record for the 67th CIPM in Qingdao, based on official event dates, dated WarriorZ photographs, and a careful component-to-application map.

WarriorZ at CIPM Qingdao 2025: Booth N2-78 Record
WarriorZ at CIPM Qingdao 2025: Booth N2-78 Record

CIPM's official history identifies the 67th Pharmaceutical Machinery Exposition in Qingdao on October 16 to 18, 2025. WarriorZ's retained article contains three original photographs with filenames dated October 18 and identifies its location as Booth N2-78. The date aligns with the official closing day. The booth number comes from WarriorZ's own record; this page does not present it as an independently confirmed organizer listing.

The old article named pneumatic components, sensor connection cables, solenoid valves, safety relays, sensors and industrial cables, with references to Festo, Murrelektronik, Pilz, Baumer and LAPP. It also claimed a formal brand relationship that is not supported by a record available for this rewrite. That claim has been removed. The categories remain useful when linked to a real pharmaceutical-packaging machine and exact request.

Event facts and evidence boundary

Item

Record

Official edition

67th Pharmaceutical Machinery Exposition

City

Qingdao, China

Official dates

October 16 to 18, 2025

WarriorZ photo record

Three original images dated October 18 in their filenames

Booth

N2-78 in the original WarriorZ page

Product scope

Automation component categories named in the original page

Not claimed

Visitor totals, customer identities, orders, performance gains or brand status

Photographs can show the booth and visible display at a point in time. They do not prove that a component improved machine output or safety, and they do not prove a commercial or brand relationship.

Component-to-application map

Factory and line

Equipment

Component category

Typical action

Pharmaceutical bottle packaging

Filler, capper, labeler, vision and cartoner

Cylinder and solenoid valve

Stop bottles, adjust guides, actuate rejects or handle cartons

Tablet and capsule packaging

Blister, tube filler, counter and cartoner

Sensors and machine cables

Detect product, position, closure, label or machine state

Secondary packaging

Case packer and palletizer

Valve manifold, I/O and connection cable

Coordinate grippers, gates, lifts and distributed signals

Cleanroom support equipment

Doors, pass boxes and material handling

Safety relay, switch and connectivity

Monitor access within a validated safety design

Machine-builder test area

Assembly and FAT

Mixed automation components

Build and test the exact circuit before shipment

These are possible uses. The table does not say that all categories were integrated into one booth demonstration or that a named brand combination forms a validated safety system.

What a component discussion needs

For a pneumatic item, bring the full code, nameplate, machine function, circuit, pressure, load, stroke, cycle, environment and failure symptom. Official Festo valve and cylinder information is model-specific. A generic photograph cannot determine coil voltage, seals, flow or mounting.

For an M8, M12 or other sensor cable, identify both devices, coding, pinout, voltage, current, signal, shielding, jacket, fixed or flexing installation, bend radius, chemicals, ingress requirement and length. Murrelektronik distinguishes cable types by conditions. A connector that mates can still have the wrong pinout or material.

For a safety relay, provide the risk assessment, safety function, input devices, output contactors, reset logic, feedback circuit, required performance and standard. Pilz publishes manuals for specific models. Safety cannot be inferred from housing color or family name.

Packaging-line examples and cautions

A bottle labeler may use cables for label-gap, bottle-presence and reject-confirmation sensors. A cylinder can operate the reject. The control must prevent an uninspected bottle from returning to the accepted stream after a fault.

A tablet tube filler may use gates, closure insertion, pressure monitoring and product sensors. The product owner defines compressed-air quality where air might contact product or critical surfaces. Fragile or moisture-sensitive tablets need handling and environmental limits that no component can replace.

A cartoner may use a valve terminal near several cylinders. Selection considers simultaneous flow, voltage, fieldbus or I/O, diagnostics, enclosure, cleaning and safe state. The manifold code and station configuration are necessary for a spare.

A safety relay is one part of a safety-related control system. Sensors, logic, outputs, wiring, diagnostics, stopping behavior and validation complete the function. A similar-looking replacement can change timing, reset, contacts or diagnostic coverage. Follow the exact manual and change-control process. Pneumatic isolation or soft start does not automatically create a safety function. Assess residual pressure, stored energy, gravity and restart.

RFQ and post-event follow-up

Request

Minimum information

Exact spare

Complete manufacturer code, quantity, photos, machine and urgency

Functional replacement

Existing data sheet, circuit, interfaces, load, cycle, environment and acceptance test

New machine component

Function, drawings, I/O, utilities, safety and quality requirements

Cable assembly

Both connectors, pinout, signal, jacket, motion, length and environment

Safety component

Risk assessment, safety function, circuit, required level and validation plan

WarriorZ is an industrial automation component and application support team. It can organize information, identify product families and prepare a supply inquiry. Final selection belongs with current manufacturer documentation, the machine builder and factory engineering, safety and quality approval.

Record quality for future articles

A future event article should link the official event page, booth or exhibitor record, dated photographs, display inventory and exact product sheets. Anonymized notes can support a summary of buyer questions. Customer names, quotations, orders and claimed improvements need separate evidence and permission.

For this page, evidence supports the 67th-edition dates, the dated photo set and WarriorZ's Booth N2-78 statement. It does not support the earlier promotional claims. That boundary makes the article a useful inquiry guide instead of an unverifiable success story.

Related WarriorZ pages

Sources and event record

These references support the event details and organizer attribution used in this article.

Evidence basis: Official event information and dated original WarriorZ photographs. Unsupported visitor counts, customer identities, and authorization claims were removed.
  1. CIPM: Previous expositions and official dates
  2. CIPM: Official exhibition information
  3. Festo: Solenoid valves
  4. Murrelektronik: Cable types for industrial applications
  5. Pilz: Safety relays and protection relays